| Rated Current (In) | Typically 630 A to 6,300 A for low-voltage air circuit breakers. | Confirm the continuous-current rating, frame size, derating data, and compatibility with the busbar system. | IEC 60947-2; rated current and temperature-rise verification. | High |
| Rated Operational Voltage (Ue) | Common low-voltage ratings include 380 V, 400 V, 415 V, 440 V, 500 V, 690 V, and up to 1,000 V AC depending on the design. | Verify the exact voltage rating at 50 Hz or 60 Hz and confirm whether the breaker is suitable for the target network. | IEC 60947-2; manufacturer technical data sheet. | High |
| Ultimate Short-Circuit Breaking Capacity (Icu) | Common product ratings range from approximately 42 kA to 120 kA, depending on voltage, frame size, and product series. | Compare Icu at the actual operating voltage rather than comparing the maximum value listed for another voltage. | IEC 60947-2 short-circuit test requirements. | Critical |
| Service Short-Circuit Breaking Capacity (Ics) | Often specified as a percentage of Icu, such as 50%, 75%, or 100%, depending on the breaker series. | Request the Ics value at the required voltage and confirm whether the breaker can be returned to service after the test sequence. | IEC 60947-2; Ics test sequence. | Critical |
| Number of Poles | Three-pole and four-pole configurations are common in low-voltage distribution systems. | Check neutral-pole switching, neutral-pole protection, phase spacing, and installation orientation. | IEC 60947-2; system design requirements. | High |
| Installation Type | Fixed and draw-out versions are widely available. | Compare cradle dimensions, connected/test/disconnected positions, shutters, mechanical interlocks, and racking mechanisms. | IEC 60947-2; product construction and safety tests. | High |
| Electronic Trip Unit | Common protection functions include long-time, short-time, instantaneous, and ground-fault protection. | Confirm adjustable pickup ranges, time delays, true RMS measurement, communication options, event records, and trip indication. | IEC 60947-2; protection coordination study. | Critical |
| Electrical Accessories | Typical options include shunt trip, undervoltage release, closing coil, motor operator, auxiliary contacts, and alarm contacts. | Verify coil voltage options, control-circuit ratings, wiring terminals, accessory compatibility, and spare-part availability. | IEC 60947-2; control and auxiliary-circuit specifications. | High |
| Mechanical and Electrical Life | The number of operating cycles varies by frame size, utilization category, operating mechanism, and accessory configuration. | Request the rated mechanical and electrical endurance separately, including the operating conditions used for testing. | IEC 60947-2 endurance tests. | Medium |
| Insulation and Impulse withstand | Low-voltage ACB designs commonly specify an insulation voltage up to 1,000 V and an impulse withstand level commonly up to 12 kV, depending on the series. | Check the exact Ui and Uimp values, clearances, creepage distances, and altitude limitations. | IEC 60947-2 dielectric and impulse tests. | High |
| Environmental Conditions | Operating temperature, humidity, altitude, pollution level, and enclosure conditions can affect the declared performance. | Ask for temperature derating, altitude correction, storage limits, humidity limits, corrosion protection, and enclosure compatibility. | IEC 60947-1 and IEC 60947-2 environmental requirements. | High |
| Factory Quality Control | Routine verification should be performed on each completed breaker before shipment. | Request routine-test records, calibration certificates, inspection plans, traceability procedures, and sample type-test reports. | IEC 60947-2 routine verification and quality-management procedures. | Critical |
| Certification and Market Access | Required documentation depends on the destination market, project specification, and applicable conformity rules. | Verify valid test reports, declarations of conformity, certification scope, report model numbers, and document authenticity. | IEC 60947 series; applicable regional conformity requirements. | Critical |
| Customization Capability | Customization may cover trip settings, control voltage, terminals, communication protocols, labels, and mechanical interfaces. | Confirm minimum order quantity, engineering-change control, drawing approval process, sample policy, and tooling responsibility. | Approved technical specification and contract documentation. | Medium |
| Lead Time and Spare Parts | Lead time depends on product configuration, production capacity, testing requirements, and accessory availability. | Compare confirmed production schedules, spare-parts stock, warranty terms, technical support, and after-sales response procedures. | Purchase contract, warranty terms, and service-level agreement. | High |
| Total Cost of Ownership | The purchase price is only one cost element; installation, testing, energy losses, maintenance, replacement parts, and downtime also affect lifecycle cost. | Compare the complete bill of materials, logistics, commissioning, maintenance intervals, warranty coverage, and expected service life. | Project cost model and approved technical specification. | High |