| Profile 01 | Miniature DC circuit breakers for control, signal and auxiliary circuits | Up to 250 V DC per pole; higher voltage configurations require series-pole verification | 1–63 A | Typically 4.5–10 kA, depending on model and test configuration | IEC 60947-2; IEC 60898-2 where applicable; relevant Chinese GB standards | DC polarity diagram, trip curve, short-circuit test report and terminal temperature-rise data | Battery cabinets, telecom systems and industrial control panels |
| Profile 02 | Molded-case DC circuit breakers for distribution feeders | 250–750 V DC, subject to pole arrangement and insulation rating | 63–800 A | Typically 15–50 kA at the specified DC voltage | IEC 60947-2; GB/T 14048.2; applicable EMC and environmental requirements | Rated ultimate and service short-circuit capacity, derating curves and coordination tables | PV combiner systems, energy storage and industrial DC distribution |
| Profile 03 | High-current molded-case breakers with adjustable electronic trip units | Up to 1,000 V DC for approved configurations | 400–1,600 A | Approximately 25–65 kA, subject to voltage, poles and test circuit | IEC 60947-2; GB/T 14048.2; project-specific EMC requirements | Protection settings, communication protocol, selectivity study and thermal derating data | Large battery energy-storage systems and DC bus protection |
| Profile 04 | Air circuit breakers adapted for high-current DC applications | Up to 1,000 V DC, only with a dedicated DC rating | 630–6,300 A | Commonly 50–100 kA in low-voltage test systems; confirm exact DC test conditions | IEC 60947-2; GB/T 14048.2; installation and pollution-degree requirements | Type-test certificate, arc-extinction method, mechanical endurance and maintenance schedule | High-power rectifiers, data-center DC systems and industrial substations |
| Profile 05 | Photovoltaic DC breakers and switch-disconnector combinations | Up to 1,500 V DC for suitably rated PV applications | 16–630 A | Typically 5–25 kA at the declared PV voltage | IEC 60947-2; IEC 60947-3; IEC 60947-1; GB/T equivalents where applicable | PV-specific test report, polarity requirements, utilization category and IP rating | Rooftop, utility-scale and commercial photovoltaic installations |
| Profile 06 | Battery energy-storage DC breakers with auxiliary and shunt-trip options | 500–1,500 V DC, depending on battery architecture | 100–2,000 A | Commonly 20–65 kA; verify prospective battery short-circuit current | IEC 60947-2; GB/T 14048.2; applicable energy-storage and fire-safety requirements | BMS interface, pre-charge coordination, emergency-trip logic and temperature derating | Containerized and cabinet-based battery storage projects |
| Profile 07 | Railway and transit DC feeder breakers | 750 V DC, 1,500 V DC or project-defined traction voltage | 630–4,000 A | Often 25–100 kA, subject to traction-network fault calculations | IEC 60947-2; IEC 60077 series where applicable; railway project specifications | High-speed interruption data, reverse-current behavior and transit-system references | Metro, light rail, railway substations and traction power systems |
| Profile 08 | Marine and offshore DC circuit breakers | 24–1,000 V DC, with marine approvals required for classified installations | 10–1,600 A | Typically 10–50 kA, depending on vessel battery and distribution design | IEC 60947-2; IEC 60092 where applicable; classification-society rules | Marine certificate, vibration and salt-mist test results, enclosure and corrosion data | Ships, offshore platforms and marine battery systems |
| Profile 09 | Fast DC breakers for battery, traction and semiconductor-protection applications | Up to 1,500 V DC, depending on the interruption technology | 100–4,000 A | Approximately 20–100 kA, with interruption time being application-critical | IEC 60947-2 and relevant product-specific technical requirements | Total clearing time, let-through energy, waveform records and repeated-fault performance | Fast-fault-clearing systems and high-value power-electronics installations |
| Profile 10 | Customized DC breakers for OEM panels and export projects | Project-specific; commonly 24–1,500 V DC | Application-specific, commonly 10–3,200 A | Must be established from the actual system fault-current calculation | IEC 60947-2; GB/T 14048.2; destination-market certification requirements | Design drawings, samples, factory acceptance test, quality plan and spare-parts commitment | OEM equipment, export control panels and engineered low-volume projects |