Pressure-Vacuum Relief Valve Weight-loaded or spring-loaded type | Atmospheric and low-pressure storage tanks containing liquids, chemicals, fuels, or water-treatment media. | Releases excess internal pressure and admits air or inert gas when tank pressure falls below the vacuum set point. Normally used for low-pressure service rather than high-pressure process protection. | Simple construction, low operating cost, easy inspection, and suitable for combined pressure and vacuum protection. | Carbon steel, stainless steel, aluminum, or corrosion-resistant alloy wetted parts. Soft seats may use PTFE, FKM, EPDM, or other application-approved elastomers. | API 2000; ISO 28300; applicable tank design code; ASME BPVC Section VIII may apply when the valve protects a pressure vessel rather than a storage tank. | Confirm required: set-pressure test certificate, vacuum-setting test, material certificates, leakage test, dimensional drawings, and coating records. PED conformity may be required in the European Economic Area depending on the equipment classification. | High for general tank-service sourcing when operating conditions are clearly defined. |
Conservation Vent Low-pressure tank vent | Fixed-roof tanks storing volatile or oxidation-sensitive products where vapor loss and air ingress must be limited. | Maintains a small positive tank pressure and opens during filling, emptying, thermal expansion, or contraction. | Reduces product evaporation, limits oxygen entry, and can help control emissions when correctly sized. | Carbon steel or stainless steel body; seat and diaphragm materials selected according to vapor composition, temperature, and chemical compatibility. | API 2000 and ISO 28300 are commonly used for tank venting calculations and requirements. Local environmental and fire regulations may also apply. | Check: certified flow capacity, pressure and vacuum set points, emissions requirements, hazardous-area installation conditions, and evidence of material compatibility. | High for storage-tank projects requiring low fugitive emissions. |
Emergency Pressure Relief Vent Hinged cover or weighted emergency vent | Large atmospheric or low-pressure tanks requiring additional relief during external fire exposure or abnormal heat input. | Provides a high-capacity emergency opening at a pressure above the normal operating vent setting. | High emergency relieving capacity, relatively simple mechanism, and useful as a supplementary protection device. | Carbon steel, stainless steel, or aluminum depending on corrosion, weight, and temperature requirements. Gaskets should be selected for the stored product and fire exposure conditions. | API 2000; ISO 28300; applicable fire-protection, tank-design, and local authority requirements. | Required verification: emergency capacity calculation, opening-pressure test, hinge or cover design information, gasket specification, and inspection procedure. | Medium because sizing is strongly dependent on tank geometry, fire case, and regulatory approval. |
| Pilot-Operated Relief Valve | Process vessels, separators, pipelines, and systems where high capacity, tight shutoff, or variable operating pressure is important. | Uses process pressure and a pilot control system to open at a defined set pressure. Normally provides pressure relief only; vacuum protection requires a separate device or combined arrangement. | Good seat tightness near set pressure, high capacity, and reduced simmering in some applications. | Carbon steel, stainless steel, low-temperature carbon steel, duplex stainless steel, or nickel alloys selected for pressure, temperature, and corrosion service. | API 520 for sizing and selection; API 526 for standardized flanged pressure-relief-valve dimensions; API 527 for seat-tightness testing; ASME BPVC Section VIII where applicable. | Confirm: ASME/National Board certification where required, set-pressure certificate, capacity certification, pilot materials, functional test records, and sour-service compliance when applicable. | Medium for global sourcing due to higher engineering, testing, and maintenance requirements. |
| Spring-Loaded Safety Relief Valve | Pressure vessels, boilers, compressors, process piping, and other pressurized equipment. | Opens when system pressure reaches the spring setting and reseats after pressure falls below the blowdown range. Vacuum protection is not normally provided. | Widely standardized, mechanically independent, available in many pressure classes, and comparatively easy to test. | Carbon steel, stainless steel, alloy steel, and corrosion-resistant trim. Spring material and bellows material must match temperature and corrosion conditions. | API 520, API 526, API 527, and ASME BPVC Section VIII. Boiler service may involve ASME Section I or other jurisdictional requirements. | Verify: code certification, set-pressure and capacity tests, stamped nameplate requirements, material traceability, and local registration rules. | High for standardized pressure-relief applications with clear code requirements. |
| Buckling-Pin Relief Valve | Applications requiring a non-reclosing pressure relief device, including selected chemical, pipeline, and pressure-vessel services. | A calibrated pin buckles at a defined pressure, allowing the valve to open rapidly. It normally requires manual replacement or reset after activation. | High resistance to vibration, long-term stability, and low sensitivity to spring fatigue in suitable designs. | Stainless steel, carbon steel, nickel alloys, and engineered polymers according to process conditions. Pin material and geometry are critical to performance. | Application-specific pressure-relief standards; API 520 and ASME requirements may apply depending on the equipment and jurisdiction. Manufacturer qualification testing is important. | Request: certified burst or buckling pressure, temperature correction data, replacement procedure, material certificates, and evidence of qualification testing. | Medium for specialized projects; less suitable where automatic reseating is mandatory. |
| Breather Valve with Flame Arrester | Storage tanks containing flammable liquids or vapors where flame transmission prevention is required in addition to normal venting. | Provides pressure and vacuum breathing functions while the flame-arrester element reduces the risk of flame propagation through the vent path. | Integrates two protective functions and can reduce piping complexity when the arrangement is properly engineered. | Stainless steel or carbon steel housing; flame element commonly uses stainless steel or other temperature-resistant metallic materials. Gaskets must be compatible with the vapor and temperature. | ISO 16852 for flame arresters; API 2000 and ISO 28300 for tank venting; ATEX 2014/34/EU or IECEx requirements may apply in hazardous-area markets. | Verify: flame-arrester test certificate, explosion group and temperature class, pressure/vacuum settings, flow capacity, installation orientation, and cleaning inspection requirements. | Medium because certification, maintenance, and hazardous-area requirements can be extensive. |
Sanitary Pressure-Vacuum Valve Hygienic vent valve | Food, beverage, pharmaceutical, biotechnology, and high-purity process tanks. | Controls low positive pressure and vacuum while minimizing product retention and contamination risk. | Cleanable construction, low dead volume, hygienic connections, and compatibility with cleaning-in-place procedures when correctly specified. | 304L or 316L stainless steel for product-contact parts; PTFE, EPDM, silicone, or FKM seals subject to temperature, cleaning chemistry, and regulatory requirements. | EHEDG design principles, 3-A Sanitary Standards where accepted by the market, ASME BPE for applicable bioprocess equipment, and relevant food-contact regulations. | Request: surface-finish certificate, elastomer compliance documents, cleanability statement, weld records where applicable, passivation records, and hygienic design drawings. | High for hygienic industries when surface finish and documentation are controlled. |
Vacuum Breaker Vacuum relief device | Tanks, vessels, piping, and systems vulnerable to collapse during draining, cooling, condensation, pump-out, or blocked-in conditions. | Admits air, nitrogen, or another specified gas when internal pressure falls below the vacuum set point. It does not normally provide overpressure relief. | Focused protection against vacuum collapse, simple operation, and easy integration with a separate pressure-relief device. | Carbon steel, stainless steel, aluminum, or lined materials; seat and seal selection depends on the admitted gas and process atmosphere. | API 2000 and ISO 28300 for storage-tank venting; vessel and piping design codes may impose additional requirements. | Confirm: vacuum set point, required air or inert-gas quality, flow capacity, leakage performance, material certificates, and installation orientation. | High when vacuum protection is the primary design requirement. |