| 6 | 28.3 | 0.222 | Confirm that the ordered size is included in the project design and applicable product standard. | Verify rib arrangement, rib height, spacing, and relative rib area against the declared product standard. | Check measured mass, dimensions, and rib geometry against the purchase specification and EN 10080 conformity documentation. |
| 8 | 50.3 | 0.395 | Use the nominal diameter for bar spacing, lap length, anchorage, and detailing calculations. | Do not approve a rib pattern by visual appearance alone; compare inspection records with the declared geometry. | Apply the dimensional and mass tolerances specified by the referenced product standard; EN 10080 is used together with that standard. |
| 10 | 78.5 | 0.617 | Ensure the nominal size matches the reinforcement schedule and the bar-marking system used on drawings. | Confirm that ribs are continuous and sufficiently distinct to provide mechanical interlock with concrete. | Record actual mass per metre and dimensional measurements during receiving inspection. |
| 12 | 113.1 | 0.888 | Check compatibility with couplers, bending tools, prefabricated cages, and minimum internal bend diameters. | Verify the relative rib area value and measurement method stated in the technical documentation. | Use the specified tolerance class or delivery standard stated in the contract; do not substitute a local tolerance without approval. |
| 14 | 153.9 | 1.21 | Confirm that the bar diameter is consistent with congestion limits at beams, columns, walls, and joints. | Compare rib height and spacing measurements with the manufacturer’s declared reference values and applicable standard. | Require traceable inspection results for diameter, mass per metre, rib geometry, and mechanical properties. |
| 16 | 201.1 | 1.58 | Use the nominal diameter when calculating development length, lap length, and reinforcement ratio. | Check that rib geometry is suitable for the specified bond and anchorage requirements. | Verify compliance using the project’s nominated conformity-assessment route and inspection frequency. |
| 20 | 314.2 | 2.47 | Confirm that available bending, cutting, and lifting equipment can safely handle the selected size. | Ensure the rib profile is compatible with the specified bond-performance requirements and test method. | Check actual delivered mass against the nominal value using the tolerance requirements of the applicable product standard. |
| 25 | 490.9 | 3.85 | Check congestion, concrete placement, coupler availability, and transport limitations before substitution. | Confirm that rib dimensions are measured according to the referenced inspection procedure. | Require heat or batch traceability and retain inspection certificates for international shipment and site acceptance. |
| 28 | 615.8 | 4.83 | Verify that the selected diameter is accepted by the structural design code and project authority. | Compare the declared rib pattern with the bond requirements used in the design calculations. | Reject or quarantine material if dimensional, rib, marking, or certificate information is incomplete. |
| 32 | 804.2 | 6.31 | Check minimum bend diameter, splice arrangement, crane capacity, and storage support requirements. | Confirm that the relative rib area meets the value required by the applicable product standard. | Use calibrated measuring equipment and document the sampling plan for diameter, mass, and rib checks. |
| 36 | 1,017.9 | 7.99 | Obtain design approval before replacing a specified diameter with another nominal size. | Assess rib geometry together with bond strength, anchorage, and crack-control requirements. | Confirm that certificates identify the applicable standard, steel grade, production batch, and test results. |
| 40 | 1,256.6 | 9.86 | Confirm fabrication plant capacity, transportation method, lifting points, and site handling procedures. | Verify that rib height and spacing remain within the declared limits over the inspected sample. | Apply the contractually specified tolerances and acceptance criteria; EN 10080 does not replace the detailed product standard. |
| 50 | 1,963.5 | 15.41 | Use only where permitted by the design, fabrication procedure, bending equipment, and project specifications. | Require documented rib measurements and confirmation of bond-related performance requirements. | Complete enhanced receiving inspection for marking, traceability, mass, dimensions, rib geometry, and certificates. |