| 1 | Define the panel construction | Panel composition | Two glass magnesium board facings with a bonded rock wool core; the core should be continuous and tightly fitted. | The facings provide surface rigidity and impact resistance, while rock wool provides thermal, acoustic, and fire-related performance. | Request a cross-section drawing, material declaration, and production specification showing the facing and core materials. |
| 2 | Check the rock wool core density | Core density | 80–150 kg/m³; select the value according to the required structural, acoustic, and fire-performance level. | Higher density generally improves rigidity and can support better acoustic performance, but it also increases panel weight and handling requirements. | Compare the declared density with a batch test report. Calculate density from measured dry mass ÷ measured core volume when sampling is permitted. |
| 3 | Match thickness to the application | Overall panel thickness | Common project ranges are approximately 50–150 mm. Select thickness based on thermal, fire, acoustic, and load requirements rather than appearance alone. | Increasing the rock wool thickness generally reduces heat transfer and improves sound absorption, while affecting weight, joints, and installation details. | Confirm the nominal thickness and tolerance on the technical drawing; measure several points across the panel, including the edges. |
| 4 | Evaluate thermal insulation | Thermal conductivity | Rock wool commonly has a declared thermal conductivity around 0.035–0.045 W/(m·K), depending on density, temperature, moisture, and test method. | Thermal conductivity and core thickness determine the approximate thermal resistance of the insulated panel. | Ask for a test or declaration stating the conductivity value, reference temperature, moisture condition, and applicable test standard. |
| 5 | Confirm fire-performance requirements | Reaction to fire and fire resistance | Rock wool is generally non-combustible or of very limited combustibility when tested as a material; the complete sandwich panel classification depends on the facings, adhesive, joints, and assembly. | A core-material claim cannot replace a fire classification for the complete panel system. | Request a current full-panel fire test or classification report for the exact thickness, facing, adhesive, joint, and installation configuration. |
| 6 | Inspect facing-board quality and moisture behavior | Glass magnesium board performance | Check board thickness, flatness, edge integrity, water absorption or dimensional stability data, and compatibility with the intended indoor or sheltered outdoor environment. | Glass magnesium boards can vary by formulation. Moisture exposure, wetting and drying, and unsupported edges may affect long-term performance. | Review the product data sheet, inspect sample edges and surfaces, and verify that the adhesive and joint sealant are compatible with the boards. |
| 7 | Check mechanical performance, joints, and tolerances | Flatness, bond strength, load capacity, and joint design | The required load capacity depends on span, support spacing, wind or service load, panel orientation, and connection details. Use the supplier’s tested values for the exact assembly. | A dense core alone does not define the panel’s allowable span or structural capacity. Poor joints can also reduce thermal, acoustic, and fire performance. | Request load tables, deflection limits, bond or delamination test results, dimensional tolerances, installation drawings, and joint details. |