| Typical bulb form | Corn-style LED replacement bulb | Corn-style LED replacement bulb with reinforced housing | High-output corn bulb with upgraded thermal design | Dimensions, base type, fixture clearance, and installation orientation |
| Common wattage range | 12–36 W | 30–80 W | 60–150 W | Actual input wattage measured at rated voltage, not only advertised wattage |
| Typical lumen range | 1,500–4,800 lm | 4,000–11,000 lm | 8,000–22,000 lm | Tested lumens, ambient temperature, integrating-sphere report, and lumen-maintenance data |
| Common efficacy target | 110–140 lm/W | 130–170 lm/W | 150–190 lm/W | Calculated efficacy from tested lumens divided by measured watts |
| Dimming compatibility | Phase-cut dimming; approximately 10–100% with compatible dimmers | Phase-cut dimming; approximately 5–100% with tested dimmers | Phase-cut or 0–10 V option, depending on configuration | Dimmer model list, minimum load, flicker behavior, start-up performance, and audible noise |
| Recommended color temperatures | 2,700 K, 3,000 K, 4,000 K, 5,000 K, 6,500 K | 3,000 K, 4,000 K, 5,000 K, 6,500 K | 3,000 K–6,500 K; custom CCT options may be available | CCT tolerance, color consistency, and application suitability |
| Color rendering | CRI ≥80 | CRI ≥80; CRI ≥90 option may be available | CRI ≥80 or ≥90, depending on LED configuration | Test report showing Ra, R9 where required, and color-consistency data |
| Input voltage | 120 V AC or 220–240 V AC | 100–277 V AC options are common | 100–277 V AC or 120–347 V AC options may be available | Rated voltage range, frequency, power factor, and regional electrical requirements |
| Power factor | ≥0.90 | ≥0.95 | ≥0.95 | Laboratory measurement at nominal input voltage and full load |
| Flicker performance | May require project-specific confirmation | Low-flicker driver option commonly available | Low-flicker or flicker-free driver option, subject to test results | Percent flicker, flicker index, and measurement method at multiple dimming levels |
| Operating temperature | Approximately −20°C to 45°C | Approximately −30°C to 50°C | Approximately −40°C to 55°C, model dependent | Temperature rating with enclosed-fixture restrictions clearly stated |
| Ingress protection | Usually dry-location rated | IP20–IP40 housing is common; higher protection may be optional | IP40–IP65 options may be available for suitable applications | IP test report, gasket construction, and whether the complete lamp—not only the housing—is tested |
| Safety and regulatory documents | Declaration of conformity and applicable electrical safety file | Safety test report, EMC report, and regional compliance documentation | Complete safety, EMC, photobiological, and market-access documentation | Certificate scope, model number, test standard, issuing laboratory, and validity |
| Relevant standards to check | IEC 60598-1, IEC 62560, IEC 62471, CISPR 15, IEC 61547 | Applicable versions of IEC 60598-1, IEC 62560, IEC 61000 series, and IEC 62471 | Applicable regional standards plus photometric, thermal, EMC, and endurance evidence | Confirm the standards match the destination market and exact product configuration |
| Estimated wholesale price* | US$2.50–6.00 per unit | US$5.00–12.00 per unit | US$10.00–25.00 per unit | Ask whether the price includes driver type, packaging, testing, customization, and shipping terms |
| Typical order quantity | 100–500 units | 300–1,000 units | 500–2,000 units | Confirm minimum order quantity, mixed-model rules, and sample-order policy |
| Sample lead time | 5–10 business days | 7–15 business days | 10–20 business days for customized specifications | Whether samples are production-equivalent and whether testing delays are included |
| Mass-production lead time | 20–35 days | 25–45 days | 35–60 days for customized or high-output models | Production schedule, component availability, inspection time, and shipping cut-off |
| Warranty term | 2–3 years | 3–5 years | 5 years is commonly offered for qualified installations | Start date, rated operating hours, labor coverage, exclusions, and remedy for failed units |
| Warranty claim threshold | Often batch-based or subject to return authorization | Replacement or credit after documented failure verification | Defined failure-rate process with technical investigation | Failure-rate threshold, evidence requirements, freight responsibility, and response time |
| Best fit for | Basic replacement projects with controlled environments | Retail, warehouse, hospitality, and general commercial projects | High-bay, retrofit, municipal, and long-runtime applications | Match thermal conditions, dimming requirements, maintenance access, and total cost of ownership |